Redis主从架构持久化存在一个问题,即前次测试的结论,持久化需要配置在主实例上才能跨越实例保证数据不丢失,这样以来主实例在持久化数据到硬 盘的过程中,势必会造成磁盘的I/O等待,经过实际测试,这个持久化写硬盘的过程给应用程序带来的影响无法忍受;因而在大多数场景下,会考虑把持久化配置 在从实例上,当主实例宕机后,通过手动或者自动的方式将从实例提升为主实例,继续提供服务!当主实例恢复后,先从原从实例上同步数据,同步完成后再恢复到 原始的主从状态!要实现这种的要求,需要有keepalive的配合,一方面keepalive提供了VIP,可以避免修改应用程序连接,同时redis 实例的配置文件监听部分也需要修改为全网监听;另一方面keepalive定时调度脚本来监控主从实例的状态,根据具体情况进行切换!本文将重点介绍下使 用keepalive实现redis主从自动failover!
环境介绍
 操作系统版本均为:rhel5.4 64bit
 redis版本:2.6.4
 redis实例端口均为:6379
 redis实例密码均为:123
 VIP:192.168.1.120
主实例为server11(192.168.1.112)
从实例为server12(192.168.1.113,开启快照持久化)
一:安装keepalive软件,server11安装完成后直接scp至server12上即可
[root@server11 ~]# wget   
    [root@server11 ~]# tar -zxvf ../tarbag/keepalived-1.1.19.tar.gz  
    [root@server11 ~]# cd keepalived-1.1.19/  
    [root@server11 ~]# ./configure --prefix=/usr/local/keepalived && make && make install
二:配置主节点server11配置文件
[root@server11 ~]# cat /usr/local/keepalived/etc/keepalived/keepalived.conf  
    ! Configuration File for keepalived  
     
    global_defs {  
     router_id LVS_DEVEL  
    }  
     
    vrrp_script Monitor_redis {  
     script "/usr/local/scripts/redis_monitor.sh"  
     interval 2   
     weight 2    
    }  
     
    vrrp_instance VI_1{   
     state MASTER  
     interface eth0  
     virtual_router_id 51  
     mcast_src_ip 192.168.1.112  
     priority  100  
     advert_int 1  
     authentication {  
     auth_type PASS  
     auth_pass password_123  
    }  
     track_script {  
     Monitor_redis  
    }  
     virtual_ipaddress {  
     192.168.1.120  
     }  
     notify_fault  /usr/local/scripts/redis_fault.sh    
     notify_stop   /usr/local/scripts/redis_stop.sh    
     
    }
三:配置从节点server12配置文件
[root@server12 ~]# cat /usr/local/keepalived/etc/keepalived/keepalived.conf  
    ! Configuration File for keepalived  
     
    global_defs {  
     router_id LVS_DEVEL  
    }  
     
    vrrp_script Monitor_redis {  
     script "/usr/local/scripts/redis_monitor.sh"  
     interval 2   
     weight 2    
    }  
     
    vrrp_instance VI_1{   
     state BACKUP   
     interface eth0  
     virtual_router_id 51  
     mcast_src_ip 192.168.1.113  
     priority  99  
     advert_int 1  
     authentication {  
     auth_type PASS  
     auth_pass password_123  
    }  
     track_script {  
     Monitor_redis  
    }  
     virtual_ipaddress {  
     192.168.1.120  
     }  
     notify_master /usr/local/scripts/redis_master.sh    
     notify_backup /usr/local/scripts/redis_backup.sh    
     notify_fault  /usr/local/scripts/redis_fault.sh    
     notify_stop   /usr/local/scripts/redis_stop.sh    
     
    }
四:准备相关的脚本,主从实例上都需要存在这些脚本,同时注意脚本需要由可执行权限