Linux 下powerpath共享磁盘名称不一致处理方法(2)

DBTest2:~ # powermt display dev=all
Pseudo name=emcpowera
CLARiiON ID=FCNCX093300010 [Storage Group 2]
Logical device ID=600601601EA02500326149A0207AE111 [LUN 10]
state=alive; policy=BasicFailover; priority=0; queued-IOs=0;
Owner: default=SP A, current=SP A       Array failover mode: 1
==============================================================================
--------------- Host ---------------   - Stor -   -- I/O Path --  -- Stats ---
###  HW Path               I/O Paths    Interf.   Mode    State   Q-IOs Errors
==============================================================================
   0 qla2xxx                  sde       SP B1     active  alive       0      0
   0 qla2xxx                  sdk       SP A1     active  alive       0      0

Pseudo name=emcpowerb
CLARiiON ID=FCNCX093300010 [Storage Group 2]
Logical device ID=600601601EA02500F22E8FC2207AE111 [LUN 11]
state=alive; policy=BasicFailover; priority=0; queued-IOs=0;
Owner: default=SP A, current=SP A       Array failover mode: 1
==============================================================================
--------------- Host ---------------   - Stor -   -- I/O Path --  -- Stats ---
###  HW Path               I/O Paths    Interf.   Mode    State   Q-IOs Errors
==============================================================================
   0 qla2xxx                  sdg       SP B1     active  alive       0      0
   0 qla2xxx                  sdl       SP A1     active  alive       0      0

Pseudo name=emcpowerc
CLARiiON ID=FCNCX093300010 [Storage Group 2]
Logical device ID=600601601EA02500FA322E81207AE111 [LUN 1]
state=alive; policy=BasicFailover; priority=0; queued-IOs=0;
Owner: default=SP A, current=SP A       Array failover mode: 1
==============================================================================
--------------- Host ---------------   - Stor -   -- I/O Path --  -- Stats ---
###  HW Path               I/O Paths    Interf.   Mode    State   Q-IOs Errors
==============================================================================
   0 qla2xxx                  sdc       SP B1     active  alive       0      0
   0 qla2xxx                  sdi       SP A1     active  alive       0      0

如上红色字体显示的,我们可以清楚的看到对于两台主机LUN对应的情况如下:

DBTEST1                                 DBTEST2

/dev/emcpowera                   /dev/emcpowerb

/dev/emcpowerb                   /dev/emcpowera

/dev/emcpowerc                  /dev/emcpowerc

本次由于安装RAC,根据规划,emcpowerb和emcpowerc分别为OCR disk和voting disk, 而emcpowera为datadg磁盘组

对于如问题我们可以处理的思路如下:

1.采用powerpath软件的管理命令可以将其伪设备名称修改为一致,具体可以参照DBTEST1的名称,在DBTEST2上做如下修改:

#emcpadm renamepseudo –s emcpowera –t emcpowerd

#emcpadm renamepseudo –s emcpowerb –t emcpowera

#emcpadm renamepseudo –s emcpowerd –t emcpowerb

更新配置后,重启下主机看看两端是否还能保持一致。

2.另外我们还可以采用如下方法,也就是保持伪设备名称不变,采用块设备,只需要绑定的raw设备一致即可

DBTEST1                                 DBTEST2

内容版权声明:除非注明,否则皆为本站原创文章。